Type: SGDH type drive.
Capacity: 1.5kw.
Voltage: three phase 400V.
Mode: torque, speed, position.
Test platform for mutual feedback of servo driver and motor.
Test platform with adjustable analog load.
A test platform with an actuator that has no load is used.
Test platform for driving the inherent load by using motor SGDV-R90F01B PDF datasheet.
Test platform using on line test method.
This test system is composed of three parts,
Were measured servo driver - motor system, the system inherent load and host computer
SGDV-R90F01B
The host computer sends the speed command signal to the servo driver, and the servo system starts to run according to the instruction.
In the course of operation, the running data of the servo system is collected by the host computer and the data acquisition circuit,
And carries on the preservation, the analysis and the display to the data SGDV-R90F01B PDF datasheet. Sigma -V series servo motor SGMJV.
Rated output: 0.75KW (750W).
Power supply voltage: AC200V.
Serial encoder: 20 bit Delta (standard).
Design sequence: standard.
Shaft end: straight shaft, without keyway (standard).
Optional: with oil seal.
Medium inertia SGDV-R90F01B PDF datasheet.
Instantaneous maximum torque (rating 350%).
Equipped with a high resolution serial encoder (13\/20 bit).
Max speed up to 6000r\/min.
Variety is complete (50 ~ 750W, with hold brake).
Use example:
Semiconductor manufacturing equipment,
Placement machine,
Punch printed circuit board,
Robot,
Handling machinery,
Food processing machinery.
Rating and specifications:
Rated time: continuous.
Vibration level: V15.
Insulation resistance: DC500V, 10M, or above.
Using ambient temperature: 0 ~ 40 degrees C.
Excitation mode: permanent magnet type.
Installation method: flange type SGDV-R90F01B PDF catalog.
Heat resistance grade: B.
Insulation withstand voltage: AC1500V 1 minutes.
Protection mode: fully enclosed self cooling type IP65 (except shaft through part).
The use of environmental humidity: 20 ~ 80%% (not dew) SGDV-R90F01B PDF catalog.
Connection mode: direct connection.
Rotation direction: clockwise direction (CCW) rotation at the load side under the direction of rotation